ZITARES INCD INCD140-70FX-30/220-240/DALI Art. no.: 10150610 Status: serie

  • CE.png
  • ENEC 10.png
  • 1101.png
  • LOGO_EL.png
  • DALI_LOGO.png

Product information

  • Intelligent and dimmable 1-channel ECG for constant current operation of LED modules
  • Non-SELV topology: high output voltages for the flexible series connection of LED modules along with high efficency
  • Advanced range of functions through individual adjustable feature via software zitares360
    • precisely adjustable output current for each channel in a wide range
    • luminous flux during operating time by compensation of the LED degradation (CLO)
    • maximum life time by control of the output current in dependency of the ECG temperature
    • DC detection: via software adjustable light level for DC operation
    • monitoring and real-time display of operating and performance data
    • simultaneous programming of up to 64 ECG
  • Highest possible flexibility thanks to adjustable output currents in a wide range via LEDset or software zitares360
  • Maximum energy efficiency of up to 94 % at maximum output load
  • Lowest ripple of output current in high- and low-frequency ranges for flicker- and glimmer-free light
  • Suitable for direct current operation and application in combination with central battery installations
  • Flicker-free and noise-free dimming in the range 1 … 100 % luminous flux
  • Push-Dim function: dimming and switching via push-button, with memory function
  • ECG extensively protected against abnormal operating conditions at the output, e.g. short-circuit, open circuit or overload
  • Certified as thermally protected ECG
  • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
  • Nominal service lifetime with a failure rate ≤ 10 %:
    50,000 h at tc = tc,max

Technical data

Mains voltage supply

Rated voltage range 220 ... 240 [V]

Battery operation

Max. admissible voltage range (continuous) 198 ... 278 [VDC]

Behaviour at mains overvoltage

Overvoltage protection 350 VAC (2 h)
Switch-off of the lamp(s) at ca. 320 VAC

Starting time

Starting time 0.5 s

Total harmonic disortion

Total harmonic distortion (max.) 10 %, at 100 % load

Power factor

Power factor 0.98

Output data

Number of channels 1
Max. total admissible power 70 W

Dimming Operation

Dimming technology (zusges.) Amplitude
Dimmverfahren DALI, Push-Dim
Dimming range (text) 1 ... 100%
Standby power max. 0.3 W

Degree of protection

ECG case IP 20

Connection terminals

Type 90°-Plug-in terminal with release hole
Wire cross section 0.5 ... 1.5 mm²
Wire stripping length 8 ... 9 mm
ECG efficiency
At 100 % load
92 %
Length (X): 280 mm
Width (Y): 30 mm
Height (Z): 21 mm
Hole spacing (XM): 270 mm
Hole spacing (ZM): 9 mm
Net Weight: 0.219 kg