ZITARES CCD CCD435-70LS-01/220-240/1-10V Art. no.: 10079000 Status: serie

  • ENEC 10.png
  • EMC VDE.png
  • CE.png
  • 1101.png
  • Logo 1-10V.png
  • SELV.png

Product information

  • Dimmable 4-channel ECG for constant current operation of LED modules
  • SELV output voltage ≤ 60 VDC for simplified luminaire construction
  • Extended range of applications by means of separated output load per channel
  • Maximum energy efficiency of up to 93 % at maximum output load
  • Lowest ripple of output current in high- and low-frequency ranges for flicker- and glimmer-free light
  • Flicker-free and noise-free dimming in the range 1 … 100 % luminous flux
  • Push-Dim function for DALI version: dimming and switching via push-button, with memory function
  • Suitable for direct current operation and application in combination with central battery installations
  • ECG extensively protected against abnormal operating conditions at the output, e.g. short-circuit, open circuit or overload
  • Certified as thermally protected ECG
  • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
  • Nominal service lifetime with a failure rate ≤ 10 %:
    50,000 h at tc = tc,max

Technical data

Mains voltage supply

Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]

Battery operation

Max. admissible voltage range (continuous) 198 ... 278 [VDC]

Behaviour at mains overvoltage

Overvoltage protection 350 VAC (2 h)
Switch-off of the lamp(s) at ca. 320 VAC

Starting time

Starting time 0.5 s

Total harmonic disortion

Total harmonic distortion (max.) 10 %, at 100 % load

Power factor

Power factor 0.98

Output data

Number of channels 4
Max. total admissible power 70 W

Temperatures

Ambient temperature ta -25 ... 55 °C
Max. admissible case temperature tc,max 80 °C

Dimming Operation

Dimming technology (zusges.) PWM
Dimmverfahren 1-10V
Dimming range (text) 1 ... 100%

Degree of protection

ECG case IP 20

Connection terminals

Type 90° push-in terminal with key
Wire cross section
Wire stripping length
ECG efficiency
At 100 % load
92
Length (X): 360 mm
Width (Y): 39 mm
Height (Z): 21 mm
Hole spacing (XM): 350 mm
Hole spacing (ZM): 9 mm
Net Weight: 0.395 kg

Downloads

  • Datasheet
  • 3D Drawing
  • ENEC Certificate
  • EC Declaration
  • EMC Certificate

Contact

Hotline

+49 2932 9000 9800

Questions? Help?
Sales contacts
Our locations
Newsletter
12